What are the reasons and solutions for the white screen when the industrial control LCD screen is turned on?
What are the reasons and solutions for the white screen when the industrial control LCD screen is turned on?
LCD industrial control LCD screen is now one of the devices that can be seen everywhere. Industrial industries have gradually used industrial control LCD screens, and industrial control LCD screens occasionally have white screens. So, how to solve the white screen failure of industrial control LCD screen? It is a very common phenomenon that the LCD industrial control LCD screen turns on the black screen or blue screen. Black screen and blue screen are problems with the system or hardware, and the white screen failure of the display screen when it turns on is generally a failure of the LCD industrial control LCD screen itself.
Causes of LCD industrial control LCD screen failure:
The white screen failure of LCD industrial control LCD screen may be caused by three aspects: problems with the LCD panel drive circuit, problems with the LCD panel power supply circuit, poor contact of the screen line, and problems with the motherboard control circuit.
If the industrial control LCD screen can be turned on normally, it means that the backlight and high-voltage generation circuit are working properly, indicating that the LCD panel has not received the drive signal; if the screen disappears after shutting down, and then a white screen occurs, it may be a problem with the power board.
This means that no matter whether it is turned on or off, as long as the power is plugged in, the high-voltage generation circuit is in working condition and the backlight source is always lit. That is to say, the high-voltage generating circuit is no longer controlled by the switch, that is, the switching signal sent by the motherboard to the high-voltage generating circuit has lost control. Since the switching signal sent by the motherboard microprocessor is generally controlled by several transistors, the fault may be that the transistor that controls the switching signal is damaged.
LCD industrial control LCD screen fault repair:
1. Remove the shell and check whether the screen line interface is loose or not connected properly.
2. Then turn on the power switch and use a multimeter to measure whether the power supply voltage of the screen line interface is normal. If the power supply voltage is normal, check whether the timing signal and drive signal in the LCD panel drive circuit are normal; if not, then check whether the fuse resistor or fuse inductor near the output end of the screen line is open or damaged. If damaged, replace the damaged components.
3. If the fuse resistor or fuse inductor near the output end of the screen line is normal, then check whether the output voltage of the DC-DC voltage conversion circuit that powers the LCD industrial control LCD screen is normal. If the output voltage is abnormal, check the fuse resistor, PWM controller, switch tube, inductor coil, filter capacitor and other components in this power supply circuit, and then replace the damaged components.
4. If the output voltage of the DC-DC voltage conversion circuit is normal, there are damaged capacitors and other components between the output of the DC-DC voltage conversion circuit and the screen line interface. Check and replace the damaged components. 5. If the power supply voltage of the screen line interface is normal, then check whether the timing signal and drive signal in the LCD panel drive circuit are normal. If not, check the output signal, input signal and power supply voltage of the chip that generates this signal to determine whether the drive chip is damaged. If damaged, replace it.
Shenzhen Zhiyan Optronics Co., Ltd. (zylcdshop.com) is a reliable China-based supplier with 18+ years of experience in high-performance LCD screens, offering quality products, customized solutions, and competitive factory-direct prices.